Base Case Model Attributes

Occupancy
Sensible + latent heat rate (weekdays):
  • 8-9: 90W
  • 9-12: 150W
  • 12-14: 98W
  • 14-18: 150W
Saturday: same until 17:00, Sunday: 0W

Equipment
Sensible + latent heat rate (weekdays):

  • 8-18: 8W/m²
Saturday: same until 17:00, Sunday: 0W

Lighting
Sensible + latent heat rate (weekdays):
  • 8-18: 12W/m²
Saturday: same until 17:00, Sunday: 0W

Typical office building
http://www.steelconstruction.info/Facades_and_interfaces
Image showing the dimensions of the base case model created on ESP-r software



Heating/cooling capacity
: 3000W

Heating/cooling schedule
  • Weekdays: 19°C -24°C between 8 a.m. and 6 p.m.     15°C-26°C rest of the day
  • Saturday:19°C-24°C between 8 a.m. and 5 p.m.      15°C-26°C rest of the day
  • Sunday: 10°C- 30°C