- Space Heating

             - Hot water

             - Electricity

 

 

bg



Mabie Farm Park - Energy Demand


Hot Water

The hot water heating requirement was calculated based on a hot water temperature of 50oC and cold water temperature of 10oC. The hot water consumptions were assumed to be:


Table 1. Hot Water Consumption


Summer visitor numbers range between 2,000 – 3,000 people per week and this falls to around 50 when the farm park is closed during the winter.

Based on the energy demand methodology, the monthly heat requirement for hot water was calculated.


Graph 1. Hot Water Demand

 

Click herefor the hot water demand spreadsheet.

 

References

  • Planning and Installing Solar Thermal Systems: A Guide for Installers, Architects and Engineers. DGS (The German Solar Energy Society), Ecofys. 2005.

 

 

  MSc: Renewable Energy Systems and the Environment
© University of Strathclyde 2010