HOT3000 |
|
| File: | obs_4_eachface.HSE |
User Weather File: C:\hotsrc\HOT2000\GUI\Debug\Dat\CWEC2.DIR
Weather Data for
Ottawa, Ontario
GENERAL HOUSE CHARACTERISTICS
| House type: | Single Detached | ||
| Number of storeys: | One storey | ||
| Plan shape: | Rectangular | ||
| Front orientation: | West | ||
| Year House Built: | 1985 |
| Occupants : |
2 Adults for 50.0% of the time |
| 2 Children for 50.0% of the time |
|
| 0 Infants for 0.0% of the time |
Sensible Internal Heat Gain From Occupants: 2.40 kWh/day
WINDOW CHARACTERISTICS
|
Label
|
Location
|
#
|
Tilt deg
|
| South | |||
| Back0001 |
Main floor3
|
1
|
90.0
|
| East | |||
| Left0001 |
Main floor4
|
1
|
90.0
|
| North | |||
| Front0001 |
Main floor1
|
1
|
90.0
|
| West | |||
| Right0001 |
Main floor2
|
1
|
90.0
|
|
Label
|
Type
|
#
|
Window Width (m)
|
Window Height (m)
|
Total Area (m2)
|
Window RSI
|
SHGC
|
| South | |||||||
| Back0001 |
234004
|
1
|
1.00
|
1.00
|
1.00
|
0.453
|
0.6043
|
| East | |||||||
| Left0001 |
234004
|
1
|
0.50
|
1.50
|
0.75
|
0.431
|
0.5690
|
| North | |||||||
| Front0001 |
234004
|
1
|
3.00
|
0.80
|
2.40
|
0.465
|
0.6246
|
| West | |||||||
| Right0001 |
234004
|
1
|
4.00
|
0.45
|
1.80
|
0.432
|
0.5762
|
WINDOW CODE SCHEDULE
|
Name
|
Internal Code
|
Description
(Glazings, Coatings, Fill, Spacer, Type, Frame) |
| 234004 |
234004
|
Double/double with 1 coat, Low-E .20 (hard1), 9 mm Argon, Metal, Picture, Vinyl, ER* = -3.17, Eff. RSI= 0.36
|
* Window Standard Energy Rating estimated for assumed dimensions, and Air tightness type: CSA - A1; Leakage rate = 2.790 m3/hr/m
BUILDING PARAMETER DETAILS
CEILING COMPONENTS
|
Construction Type
|
Code Type
|
Roof Slope
|
Heel Ht.(m)
|
Section Area (m2)
|
R. Value (RSI)
|
|
| Ceiling01 |
Attic/gable
|
User specified
|
4.0/12
|
0.13
|
94.98
|
5.21
|
MAIN WALL COMPONENTS
|
Label
|
Lintel Type
|
Fac. Dir
|
Number of Corn.
|
Number of Inter.
|
Height (m)
|
Perim. (m)
|
Area (m2)
|
R. Value (RSI)
|
| Main floor1 Type: User specified |
100
|
North
|
1
|
1
|
2.49
|
9.75
|
24.27
|
2.29
|
| Main floor2 Type: User specified |
100
|
West
|
1
|
1
|
2.49
|
9.75
|
24.27
|
2.29
|
| Main floor3 Type: User specified |
100
|
South
|
1
|
1
|
2.49
|
9.75
|
24.27
|
2.29
|
| Main floor4 Type: User specified |
100
|
East
|
1
|
1
|
2.49
|
9.75
|
24.27
|
2.29
|
DOORS
|
Label
|
Type
|
Height (m)
|
Width (m)
|
Gross Area (m2)
|
R. Value (RSI)
|
| Door-01 Loc: Main floor1 |
Steel polystyrene core
|
2.03
|
0.87
|
1.77
|
0.98 |
| Door-02 Loc: Main floor3 |
Steel polystyrene core
|
2.03
|
0.87
|
1.77
|
0.98 |
FOUNDATIONS
| Foundation Name: | Foundation - 1 | ||
| Foundation Type: | Basement | Volume: | 223.3 m3 |
| Data Type: | Library | Opening to Main Floor: | 0.00 m2 |
| Total Wall Height: | 2.35 m | Rectangular | |
| Depth Below Grade: | 1.82 m | Floor Length: | 9.75 m |
| Floor Width: | 9.75 m |
| Interior wall type: | 0000000 | R-value: | 1.33 RSI |
| Exterior wall type: | User specified | R-Value: | 0.00 RSI |
| Number of corners : | 4 | ||
| Lintel type: | Bsmnt Lintel | ||
| Added to slab type : | User specified | R-Value: | 0.00 RSI |
| Floors Above Found.: | 4231000660 | R-Value: | 0.70 RSI |
Exposed areas for: Foundation - 1
Exposed Perimeter: 38.98 m
Configuration: BCIN_1
- concrete walls and floor
- interior surface of wall insulated over full-height
- any first storey construction type
FOUNDATION CODE SCHEDULE
Added To Slab
|
Name
|
Code
|
Description
(Framing, Spacing, Insulation, Int., Sheathing) |
|
N/A, N/A, N/A, N/A, N/A
|
Floors Above Foundation
|
Name
|
Internal
Code |
Description
(Structure, typ/size, Spacing, Insul1, 2, Int., Sheathing, Exterior, Drop Framing) |
| 4231000660 |
4231000660
|
Wood frame, 38x235 mm (2x10 in), 400 mm (16 in), None, None, None, Plywood/Particle board 15.5 mm (5/8 in), Wood, No
|
|
N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A
|
ROOF CAVITY INPUTS
| Gable Ends | Total Area: | 15.83 m2 | |
| Sheathing Material | Plywood/Part. bd 9.5 mm (3/8 in) | 0.08 RSI | |
| Exterior Material: | Hollow metal/vinyl cladding | 0.11 RSI | |
| Sloped Roof | Total Area: | 100.14 m2 | |
| Sheathing Material | Plywood/Part. bd 12.7 mm (1/2 in) | 0.11 RSI | |
| Exterior Material: | Asphalt shingles | 0.08 RSI | |
| Total Cavity Volume: | 77.2 m3 | Ventilation Rate: | 0.50 ACH/hr |
AIR LEAKAGE AND VENTILATION
Building Envelope Surface Area: 378.69 m2
| Air Leakage Test Results at 50 Pa.(0.2 in H2O) = 4.65 ACH | ||
| Equivalent Leakage Area @ 10 Pa = 770.42 cm2 |
| Terrain Description | Height | m |
| @ Weather Station : Open flat terrain, grass | Anemometer | 10.0 |
| @ Building site : Suburban, forest | Bldg. Eaves | 3.3 |
| Local Shielding: | Walls: | Heavy |
| Flue : | Light |
| Leakage Fractions- | Ceiling: | 0.300 | Walls: | 0.500 | Floors: | 0.200 |
| Normalized Leakage Area @ 10 Pa: | 2.0344 cm2/m2 |
| Estimated Airflow to cause a 5 Pa Pressure Difference: | 123 L/s |
| Estimated Airflow to cause a 10 Pa Pressure Difference: | 192 L/s |
F326 VENTILATION REQUIREMENTS
| Kitchen, Living Room, Dining Room |
3 rooms @ 5.0 L/s: 15.0 L/s
|
| Utility Room |
1 rooms @ 5.0 L/s: 5.0 L/s
|
| Bedroom |
1 rooms @ 10.0 L/s: 10.0 L/s
|
| Bedroom |
2 rooms @ 5.0 L/s: 10.0 L/s
|
| Bathroom |
2 rooms @ 5.0 L/s: 10.0 L/s
|
| Other |
2 rooms @ 5.0 L/s: 10.0 L/s
|
| Basement Rooms |
: 0.0 L/s
|
SECONDARY FANS & OTHER EXHAUST APPLIANCES
|
Control |
Supply (L/s)
|
Exhaust (L/s)
|
||
| Dryer |
Continuous
|
-
|
1.20
|
|
Dryer is vented outdoors
SPACE HEATING SYSTEM
| Primary Heating Fuel: | Natural Gas |
| Equipment: | Furnace/Boiler with continuous pilot |
| Manufacturer: | Wizard SPH man |
| Model: |
| Calculated* Output Capacity: | 9.50 kW |
| * Design Heat loss X 1.10 + 0.5 kW | |
| Pilot Light energy consumption: | 25.30 MJ/day |
| Steady State Efficiency: | 78.00 % |
| Fan Mode: | Auto |
| Low Speed Fan Power: | 0 watts |
| High Speed Fan Power: | 184 watts |
| Flue Diameter: | 152.40 mm |
DOMESTIC WATER HEATING SYSTEM
| Primary Water Heating Fuel: | Natural gas |
| Water Heating Equipment: | Conventional tank |
| Energy Factor: | 0.55 |
| Manufactuer: | Wizard DHW man |
| Model: | Wizard DHW mod |
| Tank Capacity = | 151.40 Litres | Tank Blanket Insulation | 0.00 RSI |
| Tank Loacation: | Basement |
| Pilot Energy = | 0.00 MJ/day | Flue Diameter | 76.20 mm |