Analysis
of ducted wind turbines using values derived from Merit |
|
|
Annual
electrical demand for Rottenrow site |
|
KWhr |
76701 |
KWhr |
|
|
The
amount of carbon released per KWhr of elec used from the grid |
|
kg/KWhr |
0.43 |
kg/KWhr |
|
The
annual carbon released by using only electricity from the grid |
|
kg |
32981 |
kg CO2 |
|
|
|
The
type of battery used is the 415 Ah 6V battery |
|
|
|
|
|
|
|
|
|
annual electrical |
|
carbon |
|
|
anuual elec. |
annual elec. |
saving from grid |
|
saving |
|
|
excess |
deficit |
|
in KG CO2 |
|
|
number of turbines |
(KWhr) |
(KWhr) |
(KWhr) |
number of turbines |
per annum |
|
600 BP 585 PV modules |
|
|
|
plus |
|
|
|
Turbines facing |
4 |
9229.56 |
48407.9 |
28293.2 |
4 |
12166.076 |
|
|
|
due west |
6 |
9240.28 |
48343.1 |
28358 |
6 |
12193.94 |
|
|
8 |
9255.27 |
48282.3 |
28418.8 |
8 |
12220.084 |
|
|
10 |
9274.52 |
48216.5 |
28484.6 |
10 |
12248.378 |
|
|
12 |
9289.07 |
48151 |
28550.1 |
12 |
12276.543 |
|
|
14 |
9300.62 |
48084.9 |
28616.2 |
14 |
12304.966 |
|
|
16 |
9316.72 |
48022.3 |
28678.8 |
16 |
12331.884 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
annual electrical |
|
carbon |
|
|
Supply only |
|
anuual elec. |
annual elec. |
saving from grid |
|
saving |
|
from
ducted wind turbines |
excess |
deficit |
|
in KG CO2 |
|
facing due west |
number of turbines |
(KWhr) |
(KWhr) |
(KWhr) |
number of turbines |
per annum |
|
|
4 |
8.34E-07 |
76523.9 |
177.2 |
4 |
76.196 |
|
|
6 |
8.34E-07 |
76444.9 |
256.2 |
6 |
110.166 |
|
|
8 |
8.34E-07 |
76365.8 |
335.3 |
8 |
144.179 |
|
|
10 |
8.34E-07 |
76286.6 |
414.5 |
10 |
178.235 |
|
|
12 |
8.34E-07 |
76207.4 |
493.7 |
12 |
212.291 |
|
|
14 |
8.34E-07 |
76128.7 |
572.4 |
14 |
246.132 |
|
|
16 |
8.94E-07 |
76050.9 |
650.2 |
16 |
279.586 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
annual electrical |
|
carbon |
|
supply
only from ducted |
|
anuual elec. |
annual elec. |
saving from grid |
|
saving |
|
wind
turbines facing |
|
excess |
deficit |
|
in KG CO2 |
|
due south |
number of turbines |
(KWhr) |
(KWhr) |
(KWhr) |
number of turbines |
per annum |
|
|
4 |
5.96E-07 |
76597 |
104.1 |
4 |
44.763 |
|
|
6 |
6.56E-07 |
76511.3 |
189.8 |
6 |
81.614 |
|
|
8 |
1.07E-06 |
76425.7 |
275.4 |
8 |
118.422 |
|
|
10 |
6.56E-07 |
76339.8 |
361.3 |
10 |
155.359 |
|
|
12 |
1.43E-06 |
76254.3 |
446.8 |
12 |
192.124 |
|
|
14 |
8.94E-07 |
76168.8 |
532.3 |
14 |
228.889 |
|
|
16 |
5.96E-07 |
76083.7 |
617.4 |
16 |
265.482 |
|
|
|
|
|
|
|
|
|
|
|
From
the above graphs it can be interpreted that as more turbine are insalled
there is a linear increase in CO2 savings per annum |
|
|
|
It
can also been seen that the amount of power derived from the turbines facing
due west is greater than for the turbines facing due south |
|
|
It
is estimated that the maximum amount of turbines that could be installed on
the building at the Rottenrowsite is 14 facing due west and 14 facing due
south |
|
|
|
|
Combining
the amount of electricity generated from 600 BP585 modules, 14 ducted
turbines facing due south and 14 ducted turbines facing due west |
|
|
|
|
|
Supply side |
|
annual electrical |
carbon |
|
|
|
|
anuual elec. |
annual elec. |
saving from grid |
saving |
|
|
|
BP 585 600 modules |
excess |
deficit |
|
in KG CO2 |
|
|
|
+ |
(KWhr) |
(KWhr) |
(KWhr) |
per annum |
|
|
|
14 ducted turbines |
|
|
facing
due west |
|
|
+ |
9422.71 |
47624.4 |
29076.7 |
12502.981 |
|
|
14
ducted turbines |
|
|
facing
due south |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|